Quick set up PARADox ESPRIT 728 ULT V2.10 alarm2sms Programming Guide 1st Step Installer Code OR 2 8 2 8 2 8 Enter 4 digit 6 digit Flashing Program mode.
Reference & Installation Manual. 12 Reference & Installation Manual Part 4: Programming Methods The 728 Ultra and 738. can visit our website at www.paradox.
View & download of more than 106 Paradox PDF user manuals, service manuals, operating guides. Security system, Keypad user manuals, operating guides & specifications.
2 REFERENCE & INSTALLATION MANUAL PART 1: INTRODUCTION Thank you for placing your trust in Paradox and its improved Espr it 728 series control panels.
728: 10 zones (4 onboard zones + 4. it is impossible to enter programming mode. Paradox Security Systems. About Paradox 4 About This Manual 4 AC 7 Accessory.
ESPRIT 728 ULT V2.10 Quick Programming Guide To enter Programming Mode: 1. Press [ENTER] 2. Enter [2828] or [282828] (Enter key flashing), you are in the programming mode 3. Enter 3 digits ADDRESS number 4. Enter required DATA (Either enter 2 digits, 3 digits or ON / OFF relevant key) Press [ENTER] to confirm or [CLEAR] to ignore A=10, B=11/STAY, C=12/AWAY, D=BYP, E=MEM & F=TBL Remember: After keyed in a required DATA, always press ENTER and then CLEAR, in order to let the ENTER key flashing before proceed with entering the next 3 digits ADDRESS number. Step 1: To program zone type Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing · ON relevant key [1 to 10] for ZONE features wanted [key in 100][On key wants to be 24 HOUR zone] [key in 104][ON key wants to be INSTANT zone] [key in 108][ON key wants to be FOLLOW zone] Note: Zones that are not selected in [100] to [108] automatically become delay zone. [key in 096][ON key wants to be SILENT zone] [key in 116][ON key wants to be STAY zone] [key in 124][ON all zone to allow for bypass] Example: [key in 104], [ON key 2,3,4], meaning zone 2,3 & 4 are instant zone. Zone 1 is delay zone. [key in 124], [ON 1,2,3, & 4], all zones are bypassable zone Example: [key in 116], [ON key 1, 3 & 4], meaning zone 1,3 & 4 are to be protected in stay arming, zone 2 is bypassed. Example: [key in 100], [ON 3], meaning this zone 3 is a fire zone (24 hours zone) Note: If zone 3 is enable as 24 hours zone, it is a FIRE zone Example: [key in 100][ON key 4], meaning zone 4 is 24 hours zone [key in 096][ON key 4], meaning zone 4 is a silent zone (for panic button) · ON relevant key [1 to 10] for USER features wanted [key in 062][ON key 1 to 10], to allows user 1 to 10 in stay arming [key in 068][ON key 1 to 10], to allows user 1 to 10 in away/ force arming [key in 074][ON key 1 to 10], to allows user 1 to 10 to bypass zones Note: By default, master code (as user 00) allows to force and stay arming. 1 Step 2: To program features Press [ENTER] [2828] or [282828] , you are in the programming mode, ENTER key is flashing [key in 088], [ON key 1,2,3,4,5,6,7,8, 9 &12] & [OFF key MEM] [key in 090], [ON key 11 or/and 12], for keypad zone [key in 049], [enter 060], for exit delay 60 seconds [key in 050], [enter 060], for entry delay 60 seconds [key in 053], [enter 003], for zone speed 45 ms. (for vibration sensor). 004 for 60 ms, 005 for 75 ms. * Choose either Step 3A or 3B Step 3A: To call CMS Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing [key in 038][press 10 then 10], contact ID format [key in 086][ON key 7 & 12][ENTER][CLEAR], to call CMS phone. [key in 090][ON key 10][ENTER][CLEAR], to enable Duress signal. [key in 046][enter 001], for daily test [key in 047][enter HHH], for hour [key in 048][enter HHH], for minutes Press [ENTER] [2828] or [282828] ,then [7], you are in the streamline programming mode, ENTER key and 2ND are flashing. [key in 04][enter phone number 1][ENTER][CLEAR], CMS phone number 1 [key in 06][enter phone number 2][ENTER][CLEAR], CMS phone number 2 [key in 08][enter 8888 8888][ENTER][CLEAR], account number Note: to clear phone number, replace digit with [2ND] Step 3B: To call Handphone Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing [key in 037][enter 7 then 2ND], waits for 15 rings call duration [key in 038][enter TRBL then TRBL], pager format [key in 086][ON key 7, 11 & 12][ENTER][CLEAR], to call phone 1 and phone 2 each ONE time Note: if only [ON key 7 & 12, OFF key 11][ENTER][CLEAR], to call ONLY phone 1 one time [key in 090][ON key MEM], Press [ENTER] [2828] or [282828] ,then [7], you are in the streamline programming mode, ENTER key and 2ND are flashing. [key in 36][enter 33333333], to report zone 1 to 4 [key in 37][enter 33333333], to report zone 5 to 8 (program only if these zones are used) [key in 38][enter 3333], to report zone 9 to 10 [key in 64][enter 2ND 2ND 333333][ENTER][CLEAR], to report panics [key in 04][enter phone number 1][ENTER][CLEAR], handphone number 1 [key in 06][enter phone number 2][ENTER][CLEAR], handphone number 2 [key in 08][enter 8888 8888], account number 2 Others Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing 1. Keypad setting [key in 090][ON key 11][ENTER][CLEAR], for keypad zone 1 [key in 090][ON key 12][ENTER][CLEAR], for keypad zone 2 Select the jumper at the keypad, J1 OFF is keypad 1 and J1 ON is keypad 2. Power down and on again after changing the jumper setting. 2. Keyswitch [key in 086][ON key 3][ENTER][CLEAR], to enable keyswitch Connect a 500 ohm resistor in series with AUX of keypad black wire & another wire connect to GRN of keypad green wire. AUX + AUX - GRN YEL 500 ohm resistor COM NO keyswitch 3. Partitioning [key in 086][ON key 8][ENTER][CLEAR], to enable partitioning · ON relevant key [1 to 10] for ZONE to be at partition A or B [key in 116], for zone Partition A [key in 120], for zone Partition B · ON relevant key [1 to 10] for USER to use in Partition A or B [key in 062], to allows user 1 to 10 in Partition A [key in 068], to allows user 1 to 10 in Partition B Note: Once the system in Partition, Stay and Away/Force features are not available. 3 4. Doubling method 1 C 2 3 C 1K 2.2 K 2.2 K 1K Z3 Z1 Z2 Z4 728: [1/2] [3/4] [5/6] [7/8] Zone 1,3,5 & 7 use 1K resistor, zone 2,4,6 & 8 use 2.2K resistor. Keypad 1 as zone 9 and keypad 2 as zone10, need to put 1K resistor for keypad zones. [key in 090][ON key 8][ENTER], to enable zone doubling [key in 088], [ON key MEM][ENTER], disable EOL. AND program zone type in Step 1. Important note: Once the panel is in zone doubling, ALL zones are Normally Closed (NC). Note: For zone doubling, the zone speed setting in address [053] should be [004] and above to avoid false alarm caused by vibration sensors. For Fire zone connections using 4-wire smoke detector Once zone 3 is enable as FIRE zone in this zone doubling method: [key in 090][ON key 1][ENTER], to disable zone 4. [key in 100][ON key 3][ENTER], to program zone 3 as fire zone. [key in 039], press [5][0], PGM to reset smoke detector [key in 040], press [5][0], PGM to reset smoke detector [key in 042], press [2ND][6], PGM to reset smoke detector [key in 056], press [0][0][4], PGM to reset smoke detector Note: Once zone 3 is a FIRE zone, zone 4 can not be used. Now, this zone 3 is a parallel wiring.. 4 PGM AUX + AUX - 1 C 2 3 C 1K 1K 2.2 K 1K 2.2 K Z1 Z2 Z3 Z5 Z6 COM NO NO Smoke detector + · COM NC + Relay:12vDC Note: The purpose of Relay is to reset smoke power. By pressing [CLEAR] and [ENTER] key together for 3 seconds. For Fire zone connections using 2-wire smoke detector PGM AUX + AUX - 1 C 2 3 C 1K 2.2 K 1K 2.2 K Z1 Z2 Z3 Z4 2 -wire Smoke detector (NO) 2 -wire Smoke detector (NO) 1 k Note: Maximum up to 5 pcs 2-wire smoke detector. 5 728: [1/2] [3/4] [5] [7/8] [key in 086][ON key BYP][ENTER], to enable zone 2-wire smoke detector to input 3 (as zone 5 in zone doubling) 5. Utility · Walk test Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing Press [ENTER][2828][8][CLEAR], to activate walk test mode. Press [ENTER][2828][8][CLEAR], to de-activate walk test mode. · To reset panel back to factory default 1. 2. 3. 4. Remove the battery and switch OFF AC power. Short the PGM and zone 1 terminal (labeled as 1) with a wire. Power ON AC and connect the battery. Wait for 10 seconds then remove the wire. 6 User functions Normal function: Type Arming / Disarm Stay arming (Stay zone will be bypassed) Force arming (Zone opened will be bypassed, it consider arm when it closed back) Instant arming (Delay zone becomes Instant) Bypass Action [Enter 4 digit user code] [STAY][4 digit user code] [FORCE][4 digit user code] Display on 636 keypad ARM is ON ARM & STAY are ON ARM is ON [STAY][4 digit user code], during the exit delay, hold [STAY] for 3 seconds [BYP][4 digit user code][ON the button corresponding to the zone], then [ENTER]. Press [CLEAR] and [ENTER] together ARM & STAY are ON BYP is ON To Reset smoke detector after an alarm on zone 3 Default master code is [4747] or [474747] Important note: Stay zone features MUST enable in [Step 1], or else it will not function One-Touch Arming: One-touch REGULAR arming One-touch STAY arming One-touch INSTANT arming Press & hold the [key 0/10] button for 3 seconds Press & hold the [key 11/STAY] button for 3 seconds Press & hold the [key 11/STAY] button for 3 seconds, then again Press & hold again the [key 11/STAY] button for 3 seconds Panic function: Press [1] & [3] at the same time, for AUDIBLE POLICE PANIC alarm. Press [4] & [6] at the same time, for AUDIBLE MEDICAL alarm. Press [7] & [9] at the same time, for FIRE alarm. Change Master / create new user code: Press [ENTER] [Master code – 4747] [ 2 digit section, 00 for master, 01 for user 1, 02 for user 2…], then [4 digits new code][ENTER][ENTER] E.g.: [ENTER][4747][00] [5678][ENTER][ENTER], where 00 is master user and 5678 is the new master code. [ENTER][5678][02] [2222][ENTER][ENTER], where 02 is user 2 and 2222 is the new user code. [ENTER][5678][48] [5354][ENTER][ENTER], where 48 is user 48 and 5354 is the Duress code. To delete user number: Press [ENTER] [Master code – 4747] [ 2 digit section, 02 for user 2, 03 for user 3…] [press 2ND][ENTER][CLEAR] E.g.: [ENTER][4747][02][Press 2ND][ENTER][CLEAR], user 2 is deleted. 7 Chime zone: On 636 keypad Press & hold any button from [1] to [6] for 3 seconds. (Button 1 for zone 1, button 2 for zone 2…..) Press & hold any button from [1] to [6] for 3 seconds (Button 1 for zone 1, button 2 for zone 2…..) Press & hold button [8] Press & hold button [9] To activate chime for zone To deactivate chime for zone To activate/deactivate chime for keypad zone To activate/deactivate Buzzer Mute Clear TBL 8 – Timer loss Press [master code:4747] [MEM] [HH:MM][ENTER] E.g.: Press [ENTER][4747][MEM] [15:35][ENTER], enter current time 3:35pm. V2.10 29092005 8
Manual Security System Paradox Esprit 738 EXPRESS Installation Manual. Paradox ESPRIT 728 ULT Quick Programming Manual. Esprit 728 Ultra & 738 Ultra - 2 -.
ESPRIT 728 ULT
1 ESPRIT 728 ULT QuickProgramming Guide V2.10 To enter Programming Mode: 1. Press [ENTER] 2. Enter [2828] or [282828] (Enter key flashing), you are in the programming.
To activate “key access programming”, press [ENTER], followed by installer, master or user code 1. (Code required depends. 728+ : Programming Guide Keywords.